Calibration of Troitsk Nu-Mass Detector Readout Electronics by Signal Digital Filters

Capa

Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

We present the results of tuning and calibration of the detector electronics in the signal digitization mode. The goal of the experiment is to search for a possible sterile neutrino signature in tritium beta-decay. The read-out electronics work in direct oscilloscope mode, which requires to optimize time frame the with the goal to minimize noise and energy resolution. We use a 7-pixel silicon drift detector (SDD) and a CMOS charge sensitive preamplifier with very low integration capacitor. Amplifier forms a slowly rising output shape and operates in pulse-reset mode. The 125 MHz ADC digitizes the signals. Using calibration data from Fe55 and Am241 gamma sources we check triangular and trapezoid digital filters to obtain the best noise and energy resolution performance. We are also examining the option to differentiate the output signal.

Sobre autores

S. Abdiganieva

Institute for Nuclear Research, Russian Academy of Sciences; Moscow Institute of Physics and Technology

Email: pantuev@inr.ru
117312, Moscow, Russia; 141700, Dolgoprudny, Moscow oblast, Russia

A. Berlev

Institute for Nuclear Research, Russian Academy of Sciences

Email: pantuev@inr.ru
117312, Moscow, Russia

M. Bochkov

Institute for Nuclear Research, Russian Academy of Sciences; Moscow Institute of Physics and Technology

Email: pantuev@inr.ru
117312, Moscow, Russia; 141700, Dolgoprudny, Moscow oblast, Russia

N. Likhovid

Institute for Nuclear Research, Russian Academy of Sciences

Email: pantuev@inr.ru
117312, Moscow, Russia

V. Pantuev

Institute for Nuclear Research, Russian Academy of Sciences; Moscow Institute of Physics and Technology

Email: pantuev@inr.ru
117312, Moscow, Russia; 141700, Dolgoprudny, Moscow oblast, Russia

S. Zadorozhnyy

Institute for Nuclear Research, Russian Academy of Sciences

Autor responsável pela correspondência
Email: pantuev@inr.ru
117312, Moscow, Russia

Bibliografia

  1. P. Lechner et al., Nucl. Instr. Meth. A 458, 281 (2001); doi.org/10.1016/S0168-9002(00)00872-X.
  2. D. N. Abdurashitov et al., JINST 10, T10005 (2015); doi: 10.1088/1748-0221/10/10/T10005; arXiv:1504.00544; physics.ins-det.
  3. A. I. Belesev et al., J. Phys. G 41, 015001 (2014); doi: 10.1088/0954-3899/41/1/015001; arXiv:1307.5687.
  4. https://www.xglab.it/products/cube-bias-boards
  5. T. Brunst et al., JINST 14, P11013 (2019); doi: 10.1088/1748-0221/14/11/P11013.
  6. V. D. Kekelidze et al., Eur. Phys. J. A 52, 211 (2016); doi: 10.1140/epja/i2016-16211-2.
  7. A. Niculae et al., Nucl. Instr. Meth. A 568, 336 (2006); doi: 10.1016/j.nima.2006.06.025.
  8. F. S. Goulding and D. A. Landis, IEEE Trans. Nucl. Sci. 35, 119(1988); doi: 10.1109/23.12687.

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Russian Academy of Sciences, 2023